61
Mascot LX Service Manual
Flat Plate Heat Exchanger - Combi Units (MLXC)
On a “Combi” unit (central heat plus domestic hot water),
the hot water is produced by a flat plate heat exchanger
located under the rear of the unit. See Fig. B24-1.
Over time, the interior of the heat exchanger can be-
come coated with a mineral buildup that reduces the
heat transfer. In some cases it is possible to pump a
cleaning solution through the exchanger and revive
it. (Laars recommends straight white vinegar for this
purpose.) If this does not improve the performance, the
exchanger must be replaced.
Replacement Procedure:
The heat exchanger on this unit has been designed to
be easy to replace. At each end of the assembly, the
piping is connected by quick-disconnects. See Fig.
B24-2. To remove one of the fittings, first cut the black
Ty-Wrap. Next, pull out the metal locking pin. To recon-
nect, insert the locking pin, then install a new Ty-Wrap.
Fig. B24-1 - Flat Plate Water Heat Exchanger
Fig. B24-2 - Quick-Disconnects for Heat Exchanger