2R4/2R5/2R6
6-67
Contents
Adjust On/Off timing of the transfer high voltage output.
Purpose
Prevent paper from being rolled up by the drum.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Timing 1st
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
3.Press the [Start] key to set the setting value.
Setting: Timing 2nd
1.Select the item to set.
2.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
U128
Leading edge timing
(Message: Adj Trans Timing)
Items
Contents
Timing 1st
Transfer On timing adjustment value (1st side)
Timing 2nd
Transfer On timing adjustment value (2nd side)
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
On Timing
Transfer On timing adjustment
value
-200 to 200
0
0.5mm
Off Timing
Transfer Off timing adjustment
value
-200 to 200
0
0.5mm
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
1side < 60
Secondary transfer voltage on tim-
ing (1st side, weight less than
60gsm)
-200 to 200
0
0.5mm
1side >= 60
Secondary transfer voltage on tim-
ing (1st side, weight 60gsm or
more)
-200 to 200
0
0.5mm
2side < 60
Secondary transfer voltage on tim-
ing (2nd side, weight less than
60gsm)
-200 to 200
0
0.5mm
2side >= 60
Secondary transfer voltage on tim-
ing (2nd side, weight 60gsm or
more)
-200 to 200
0
0.5mm
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...