2R4/2R5/2R6
6-42
Contents
Adjusts the center line for the table scanning.
Purpose
Adjusted if there is a regular error between the center lines of the copy image and original.
Adjustment
1.Press the [Start] key.
2.Press the [System Menu/Counter] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu/Counter] key.
5.Select the item to adjust.
1.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
For the copy example 1, decrease the value.
For the copy example 2, increase the value.
* :When the setting value is increased, the image moves to left, and it moves to right when the
setting value is decreased.
Figure 6-10
2.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(P.6-228) > U065(P.6-238) > U067
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U067
Adjusting the table scanning center line
(Message: Table Center)
Items
Contents
Setting range
Initial
setting
Data
variation
Front
Adjusts the scanner center line
-40 to 40
0
0.085
mm
Rotate
Scanner center line (rotate copying)
-40 to 40
0
0.085
mm
Original
Copy
example 1
Copy
example 2
Center line of the copy image
(within ± 2.0 mm)
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...