2R4/2R5/2R6-3
6-341
6.Press the [Start] key.
7.Select [Table(ChartA)].
8.Press the [Start] key to start Auto adjustment.
9.When automatic adjustment has normally completed, [OK] is displayed.
If the image position is shifted largely at the DP adjustment below, an error might occur when
adjusting it with ChartA. First, use ChartB (image position) to adjust it and then use ChartA
(color).
Method: DP FU (Chart B)
* :Adjusting the first side of the DP duplex scanning
1.Set the specified original (P/N: 7505000106) face-up on the DP.
2.Enter maintenance item U411.
3.Select [DP FU(ChartB)].
4.Press the [Start] key to start Auto adjustment.
5.When automatic adjustment has normally completed, [OK] is displayed.
Method: DP FD (Chart B)
* :Adjusting the second side of the DP duplex scanning
1.Set the specified original (P/N: 7505000106) face-up on the DP.
2.Enter maintenance item U411.
3.Select [DP FD(ChartB)].
4.Press the [Start] key to start Auto adjustment.
5.When automatic adjustment has normally completed, [OK] is displayed.
Method: DP FU (Chart A)
Automatic input of the target value
1.Set the specified original (P/N: 7505000107) face-up on the DP.
2.Enter maintenance item U411.
3.Select [Target].
4.Select [Auto].
5.Press the [Start] key.
6.Select [DP FU(ChartA)].
7.Press the [Start] key to read the barcode of the original chart and to start the automatic adjust-
ment.
8.When automatic adjustment has normally completed, [OK] is displayed.
* :When the error code "1e" or "1f" is displayed during the automatic adjustment in the DP
scanning and the barcode is not read, adjust the following after manually inputting the target
value.
Manual input of the target value
1.Enter the target values which are shown on the lower part of the front page of the adjustment
original (P/N: 7505000107) by executing the maintenance mode U425.
2.Set the specified original (P/N: 7505000107) face-up on the DP.
3.Enter maintenance item U411.
4.Select [Target].
5.Select [U425].
6.Press the [Start] key.
7.Select [DP FU(ChartA)].
8.Press the [Start] key to start Auto adjustment.
9.When automatic adjustment has normally completed, [OK] is displayed.
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...