2R4/2R5/2R6
6-65
Contents
Set the drum sensitivity.
Purpose
Execute when the drum unit or laser scanner unit is replaced.
After completing, execute maintenance mode U464 [Calibration].
Method
1.Press the [Start] key.
2.Select [Execute].
3.Press the [Start] key.
* :Starts the drum setup operation.
4.Turn the power switch off then on. Wait more than 5 seconds between the power off and on.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Contents
Displays the drum drive distance counter.
Purpose
Execute to displays the drum drive distance counter.
Method
1.Press the [Start] key.
* :Displays the count.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U119
Setting the drum
(Message: Set Drum)
Items
Contents
Execute
Detect the main charge current and save the current value.
U120
Drum drive distance counter
(Message: Drum Drv Dist Cnt)
Items
Contents
C
Displays the cyan drum drive distance counter
M
Displays the magenta drum drive distance counter
Y
Displays the yellow drum drive distance counter
K
Displays the black drum drive distance counter
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...