Set the primary transfer control voltage
Purpose
Change setting if a failure such as faint image, etc. occurs.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Normal
1.Select the item to set.
2.By using the [+] [-] keys or the numeric keys, change the setting value.
*1
:35ppm model,
*2
: 40ppm model
3.Press the [Start] key to set the setting value.
U101
Primary transfer voltage adjustment
(Message: Adjust 1st Transfer Voltage Output)
Items
Contents
Normal
Set the primary transfer voltage
Add Color
Sets 2nd side additional value
Add Color 2nd
Sets the 2nd side additional value (in reference to the 1st side additional
value)
Surround Correct
Setting the environmental correction
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Full
Yellow primary transfer voltage (full
speed)
0 to 400
70
*1
110
*2
-
Half
Yellow primary transfer voltage (half
speed)
0 to 400
45
*1
65
*2
-
3/4
Yellow primary transfer voltage (3/4
speed)
0 to 400
58
*1
88
*2
-
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...