2R4/2R5/2R6
6-356
Contents
Set permission/prohibition of the ID correction operation (calibration). Executes each setting of
the calibration.
Purpose
Execute the calibration setting when an image failure occurs or depending on the user’s request.
Execute Calibration when replacing the maintenance kit.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Setting: Permission
1.Select [On] or [Off].
* :Initial setting: On
2.Press the [Start] key to set the setting value.
Setting: Time Interval
1.By using the [+] [-] keys or the numeric keys, change the setting value.
*1: 40 ppm model
* :Setting is changeable in 10 count increments.
2.Press the [Start] key to set the setting value.
U464
ID correction setting
(Message: Set ID Adjustment Mode)
Items
Contents
Permission
Permit/Prohibit Calibration
Time Interval
Sets the time interval to execute calibration after completing printing.
Mode
Color print mode setting
Leaving Time
Setting the time to determine whether to execute calibration when recov-
ering from Sleep mode
Target Value
Setting the target sensor value for the thick layer calibration and light
intensity calibration
Calib
Executing Calibration
Items
Contents
On
Permitting Calibration
Off
Prohibiting Calibration
Items
Contents
Setting
range
Initial setting
Time(sec)
Calibration interval
0 to 9999
1200/900
*1
(sec)
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...