Adjust the magnification in the main and sub scanning direction of the table scanning.
Purpose
Adjusts the magnification in the main and sub scanning direction of the table scanning if the
above incorrect
Precautions
The magnification adjustment in the main scanning direction could cause black streaks depend-
ing on the content of the original document.
Adjust the magnification of the scanner in the following order.
U065(main scanning direction)(P.6-238)>U065((sub scanning direction)(P.6-238)
Method
1.Press the [Start] key.
2.Press the [System Menu/Counter] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu/Counter] key.
5.Select the item to adjust.
Adjustment: Main Scan
1.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image widens, and it narrows when the setting
value is decreased.
Figure 6-7
2.Press the [Start] key to set the setting value.
Adjustment: Sub Scan
1.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
U065
Adjusting the magnification for table scanning
(Message: Adj Scn)
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
Main Scan
Scanner magnification in the main scan-
ning direction
-15 to 15
0
0.10%
Sub Scan
Adjusts scanner magnification in the sub-
scanning direction
-25 to 25
0
0.10%
Original
Copy
example 1
Copy
example 2
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...