2R4/2R5/2R6
6-239
Adjustment: Sub Scan
1.By using the [+] [-] keys or the numeric keys, change the setting value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image get longer, and it shortens when the setting
value is decreased.
Figure 6-32
2.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Original
Copy
example 1
Copy
example 2