2R4/2R5/2R6
6-32
* :When the setting value is increased, the image moves backward, and it moves forward
when the setting value is decreased.
Figure 6-4
6.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034 > U066 (P.6-240) > U071 (P.6-244)
Adjustment: LSU Out Left
1.Select the item to adjust.
2.Press the [System Menu/Counter] key.
3.Press the [Start] key to output a test pattern.
4.Press the [System Menu/Counter] key.
5.Press the [
Ż
] [
Ź
] keys or the numeric keys to change the counter value.
For the test pattern 1, increase the value.
For the test pattern 2, decrease the value.
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
MPT
Adjust the center line for the MP tray
-3.0 to 3.0
0
0.1mm
Cass1
Adjust the center line for cassette 1 feed
-3.0 to 3.0
0
0.1mm
Cass2
Adjust the center line for cassette 2
(Optional unit) feed
-3.0 to 3.0
0
0.1mm
Cass3
Adjust the center line for cassette 3
(Optional unit) feed
-3.0 to 3.0
0
0.1mm
Cass4
Adjust the center line for cassette 4
(Optional unit) feed
-3.0 to 3.0
0
0.1mm
Duplex
Adjusting the center line when duplex
copying (Back page)
-3.0 to 3.0
0
0.1mm
A
A
A
Center line
(within ± 1.0 mm)
Correct image
Output
example 1
Output
example 2
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...