2R4/2R5/2R6
6-333
Contents
Adjusts the margins for the table scanning.
Purpose
Make the adjustment if margins are incorrect
Adjustment
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select the item to adjust.
6.By using the [+] [-] keys or the numeric keys, change the setting value.
* :When the setting value is increased, the margin widens, and it narrows when the setting
value is decreased.
Figure 6-40
7.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in
the maintenance mode.
U034(P.6-228) > U402(P.6-332) > U403
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U403
Adjusting margins for scanning an original on the contact
glass
(Message: Adjust Scanning Margin(Table))
Items
Contents
Setting range
Initial
setting
Data
varia-
tion
A Margin
Adjusts the scanner left margin
0.0 to 10.0
2.0
0.5mm
B Margin
Adjusts the scanner leading edge margin. 0.0 to 10.0
2.0
0.5mm
C Margin
Adjusts the scanner right margin
0.0 to 10.0
2.0
0.5mm
D Margin
Adjusts the scanner trailing edge margin
0.0 to 10.0
2.0
0.5mm
Left margin
(Within 4.0mm)
Right margin
(Within 4.0mm)
Trailing edge margin
(Within 4.0mm)
Leading edge margin
(
4.0 +1.5/-0
mm)
A
Содержание TASKalfa 306ci
Страница 36: ...2R4 2R5 2R6 2 6 35 ...
Страница 137: ...2R4 2R5 2R6 6 136 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...
Страница 191: ...2R4 2R5 2R6 2 6 190 ...
Страница 233: ...2R4 2R5 2R6 6 232 ...
Страница 266: ...2R4 2R5 2R6 6 265 1 35ppm model 2 40ppm model ...
Страница 280: ...2R4 2R5 2R6 6 279 ...
Страница 362: ...2R4 2R5 2R6 6 361 Completion Press the Stop key The screen for selecting a maintenance item No is displayed ...