2DA/2DB-1
1-6-48
(5) Detaching and refitting the heat roller
Follow the procedure below to replace the heat roller.
Procedure
1. Remove the fixing unit and separate the fix-
ing right unit and left unit (see pages 1-6-43
,
45).
2. Remove the heat roller separation claws.
(see page 1-6-47).
3. Pull out the heat roller bushing from the fix-
ing left unit and then remove the heat roller.
4. Replace the heat roller and refit all the
removed parts.
Figure 1-6-87
Fixing left unit
Heat roller
Heat roller bushing
Heat roller bushing