2DA/2DB
1-5-23
C6000
Broken fixing heater wire
In fixing warm-up, the time to reach
50
°
C/122
°
F exceeds 13.5 s, the time to
reach 100
°
C/212
°
F exceeds 10 s, the
time to reach the primary stabilization
exceeds 10 s or the time to reach the
secondary stabilization exceeds 24 s.
Fixing heater M or
S installed incor-
rectly.
Check and reinstall if necessary.
Broken fixing
heater M or S wire.
Check for continuity. If none, replace the fix-
ing heater M or S.
C6020
Abnormally high fixing unit ther-
mistor temperature
The fixing temperature exceeds 230
°
C/
446
°
F for 40 ms.
Shorted thermistor. Measure the resistance. If it is 0
Ω
, replace
the thermistor.
Broken heater con-
trol circuit on the
power supply PCB.
Replace the power supply PCB and check
for correct operation.
C6050
Abnormally low fixing unit thermistor
temperature
The fixing temperature remains below
90
°
C/194
°
F for 1 s.
Poor contact in the
thermistor connec-
tor terminals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Broken fixing ther-
mistor wire.
Measure the resistance. If it is
∞
Ω
, replace
the fixing thermistor.
Fixing thermistor
installed incor-
rectly.
Check and reinstall if necessary.
Fixing thermostat
triggered.
Check for continuity. If none, replace the fix-
ing thermostat.
Fixing heater M or
S installed incor-
rectly.
Check and reinstall if necessary.
Broken fixing
heater M or S wire.
Check for continuity. If none, replace the fix-
ing heater M or S.
C6400
Zero-crossing signal problem
The engine PCB does not detect the
zero-crossing signal for the time speci-
fied below. At power-on: 3 s Others: 5 s
Poor contact in the
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective power
supply PCB.
Check if the zero-crossing signal is output
from YC2-5 on the power supply PCB. If not,
replace the power supply PCB.
Defective engine
PCB.
Replace the engine PCB if C6400 is
detected while YC2-5 on the power supply
PCB outputs the zero-crossing signal.
C7800
Broken external temperature ther-
mistor
The input voltage is 0.5 V or less.
Poor contact in the
humidity sensor
connector termi-
nals.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
remedy or replace the cable.
Defective humidity
sensor.
Replace the drawer PCB and check for cor-
rect operation.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Содержание KM-1650
Страница 1: ...SERVICE MANUAL Published in June 05 2DA70763 Revision 3 KM 1650 2050 ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 248: ...2DA 2DB 1 2 3 2 Figure 2 3 2 Power source PCB silk screen diagram 220 240 V AC 120 V AC ...
Страница 265: ...2DA 2DB 1 2 3 19 Figure 2 3 10 Operation unit PCB silk screen diagram ...
Страница 280: ......