2-60
The main unit setup procedure > Adjustment
[CONFIDENTIAL]
U755 Conveying CIS print position adjustment
1
Enter U755 [Adj Conv CIS]
2
Select [Center Pos Adj].
3
Set A4/LTR vertically in upper cassette 1.
4
Select [Print] key to output the adjustment chart.
5
Place back the printed chart in cassette and print on back side.
6
Press [Start] key to output the adjustment chart.
7
Find the leftmost point on the scale line that cross with the horizontal line and read
the value by the scale line as V value.
8
Find the closest position of the line on face and back on the chart as H value.
9
Press [Stop] key.
10
Select [Regist].
11
Change the setting value by using [+] [-] keys or the numeric keys.
12
Press [Start] key to set the setting value.
13
Select [Print (Check)] and press [Start] key to output the test chart.
Adjust V value below 0.5 and H value to 0.
Содержание AK-9110
Страница 9: ...This page is intentionally left blank ...