2-1
The main unit setup procedure >
[CONFIDENTIAL]
2 The main unit setup procedure
Unpacking
Take out the main unit and accessories
from the packing.
•
Remove all packing materials.
(Remove the outer case after removing the ink case and the cleaning liquid.)
•
Set a slope and take the main unit down from the skid.
(Do not hold up only with the handles in the main unit.)
Installation
Cassette lift plate
•
Pull out the cassette and remove the stopper for the lift plate.
Deck lift plate
•
Pull out the deck and remove the stopper for the lift plate.
Scanner carriage
(C3100 error comes up unless not to release)
•
Remove the scanner carriage stopper and put it back in an opposite way.
Image conveying unit
(Remove the fixing screws and the plates)
•
Pull out the image conveying unit and remove the screws for the image conveying unit
•
Place the image conveying unit on a table and remove the fixing plates for the unit.
Head Treatment unit
(Remove the fixing plates)
•
Remove the fixing parts for the cap unit.
•
Remove the plates for the head treatment unit.
Adjust the machine level
•
Adjust the horizontal level of the machine with four level bolts of the main unit.
Install the right tray
•
Attach the paper width guide and the right exit tray.
Attaching national language labels
•
Affix the applicable language label
Install the ink container
Installation of the cleaning tank
•
Insert the vent spacer under the cap.