5-8
Corrective action when service call occur > C2100
[CONFIDENTIAL]
5 - 3 C2260
Check the condition of the sensor by U704 and compare with the following combination. Then, adjust the unit position
that has a gap.
(1) Setup position
No
Item
Description
Status
1
WC HP
Treatment carriage HP sensor
ON
2
WC
Treatment carriage head lower sensor
OFF
3
Cap Unit HP
Treatment cap HP sensor
ON
4
WL HP
Treatment lift HP sensor
ON
5
WL Cap Carry
Treatment lift cap conveying sensor
OFF
6
WL Cap
Treatment lift cap position sensor
OFF
7
WL Wipe
Treatment lift wipe position sensor
OFF
8
Wipe HP
Wiping blade HP sensor
ON
9
Wipe Start
Wiping blade start position sensor
OFF
10
Gap Adj 1
Discharge distance adjust sensor
ON
11
Gap Adj 2
Discharge distance adjust sensor
OFF
12
Gap Adj 3
Discharge distance adjust sensor
OFF
13
Gap Adj 4
Discharge distance adjust sensor
OFF
14
FU Upper 1
Image conveying upper limit sensor 1
OFF
15
FU Upper 2
Image conveying upper limit sensor 2
OFF
16
FU Pull
Image conveying unit-out position sensor
ON or OFF
17
FU Lower
Image conveying lower limit sensor
OFF
18
FU Reverse
Image conveying unit lift wire reverse sensor
OFF
Wipe unit
Cap unit
3
7
6
5
4
1
8
9
10
13
14
11 12
2
15