EN 44 Installation
Automatic fuse machine | Automatic
switch, at least type B or C: switch the tum-
bler switch from 1 [on] to 0 [off].
Earth leakage contact breaker | Turn the
main switch from 1 [0n] to 0 [off] or press
the test button.
Attention: Make sure that the net ten-
sion cannot accidentally be switched
on again.
Replacing the connection cable
The connection cable may only be replaced
by an original Küppersbusch cable. This ca-
ble may only be replaced by Küppersbusch,
or by a fitter or certified electrician, appoin-
ted by Küppersbusch. The applicable rated
loads can be found on the type plate on the
appliance.
5.2 Gas nozzles
This gas hob is fitted with a G25/25 (for
Dutch natural gas) gas nozzle kit. To adapt
the hob for installation to another type of
gas, both the nozzles for minimum and
maximum position must be replaced. The
replacement of another gas nozzle kit must
be executed by a certified fitter.
5.2.1 Adjusting the minimum position
gas nozzles to LPG [bottle gas]
The minimum position nozzles are placed in
the gas taps. To adjust these, first remove
knob, spring and position indicator ring.
These nozzles are adjusted for use with na-
tural gas [G25/25 and G20/20]. To adjust
these to LPG, the nozzle has to be tightened
[clockwise], until closure.
5.2.1.1 Minimum position gas nozzles
for wok burner
The wok burner is a double-ring burner, with
a double gas tap as well and therefore with
2 minimum position gas nozzles: one for the
outer rind and one for the inner ring.
Minimum position
nozzle outer ring
Minimum position
nozzle inner ring
Содержание GMS9751.0E
Страница 2: ...NE 2 ...
Страница 25: ...NE 25 ...
Страница 49: ...EN 49 Electrical diagram ...
Страница 51: ...EN 51 Notes ...
Страница 52: ...EN 52 Notes ...
Страница 75: ...DE 75 ...
Страница 77: ...DE 77 Notizen ...