EN 46
5.2.2.2 Maximum position gas nozzles
for power/standard/simmer burner
These burners are single burners, with just
1 gas nozzle for maximum position. Before
exchanging the nozzles, please remove all
separate burner components. You can now
directly see the nozzle from above.
The nozzles are marked with a number
code, indicating the dimensions of the aper-
ture. (diameter x 100)
5.2.3 Testing the burners
Place back the nozzle parts carefully [ensu-
re a correct fitting] and test the burners af-
ter that.
5.3 Gas connection
The GMS9751.0E appliance may only be fit-
ted or modified for different gas types by a
certified fitter. The fitter is responsible for a
proper functioning of the appliance, on the
location where it is in use.
The gas connection must be positioned in
such as way that it can be connected to the
gas supply, inside or outside the cabinet.
The gas tap must be visible and accessible,
eventually after opening a door of the kit-
chen cabinet.
Ask your local gas company which type of
gas you get supplied and compare this with
the data on the type plate.
The GMS9751.0E appliance must be instal-
led to the gas supply according to all cur-
rent and local requirements and guide lines.
The appliance can be connected with a per-
manent or removable connection. In case of
a removable connection, the safety adaptor
and safety gas hose with connector accor-
ding to DIN 3383 part 1, must be used.
power
standard
simmer
natural gas
G25/25-
G25/20
130
098
072
natural gas
G20/20
127
095
072
LPG G30/30
089
065
050
Maximum position
nozzle