EN 45 Installation
5.2.1.2 Minimum position gas nozzles
for power/standard/simmer burner
These burners are single burners, with sin-
gle functioning gas taps and have just 1 gas
nozzle for minimum position.
5.2.1.3 Adjusting the minimum position
gas nozzles to natural gas
To adjust the hob to natural gas, the gas
nozzles in the gas tap have to be unscrewed
[counter clockwise], until the burner con-
cerned remains burning stabile at its “lo-
west flame size’ position [see chapter 3]
and does not extinct spontaneously.
5.2.2 Exchanging the maximum positi-
on nozzles
The maximum position nozzles are placed in
the burners and must be replaced, if the hob
is fitted to another gas type.
5.2.2.1 Maximum position gas nozzles for
wok burner
The wok burner is a double-ring burner, with a
double gas tap as well and therefore with 2
maximum position gas nozzles: one for the
outer ring and one for the inner ring. Before
exchanging the nozzles, please remove all se-
parate burner components. The maximum po-
sition nozzle for the outer ring has the largest
aperture and is placed on the left rear side. The
maximum position nozzle for the inner ring has
the smallest aperture and is placed on the right
rear side.
Make sure that the maximum position
nozzle for inner and outer ring are
placed correctly, if switched the bur-
ner will not function!
The nozzles are marked with a number
code, indicating the dimensions of the aper-
ture. (diameter x 100)
Minimum position
nozzle single tap
wok 5.0kW
outer ring
inner ring
natural gas G25/25
155
075
natural gas G20/20
148
075
LPG G30/30
095
046
Maximum position
nozzle outer ring
(with larger aperture)
Maximum position
nozzle outer ring
(with smaller aperture)