Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
KUKA.PLC mxAutomation Logix 1.0
8.3
Error in the function block
466
ERROR SETTING
OUTPUT
Error writing an output. The out-
put may already be assigned by
the system.
Use a different digital output
(parameter
Number
):
1 … 2,048
467
ERROR SETTING
SOFTEND
An error occurred when writing
a software limit switch.
One possible error, for exam-
ple, is writing a rotational axis
with a value outside the range
+/-360°.
Program valid values for the
software limit switches (see
machine data).
No.
Message text
Cause
Remedy
No.
Message text
Cause
Remedy
501
INTERNAL ERROR
Internal exceptional error
Contact KUKA Roboter GmbH.
(
>>>
502
INVALID
BUFFER_MODE
BufferMode
0
: DIRECT is not
permissible for this function
block.
Program the correct mode:
1
: ABORTING
2
: BUFFERED
503
INVALID MXA VER-
SION
The software versions of the
mxA interface and PLC library
are not compatible.
Install compatible software ver-
sions on the robot controller
and PLC.
(
>>>
504
INVALID OVER-
RIDE
Invalid override value in the
function block
KRC_SetOverride
Program a valid value (parame-
ter
Override
).
0 … 100%
505
MAX GROUP REF
IDX REACHED
The axis group index specified
in the function block
KRC_ReadAxisGroup is
already assigned.
Only instance the
KRC_ReadAxisGroup function
block once in a program.
506
INVALID GROU-
PREFIDX
The axis group index specified
in the function block is invalid.
Specify a valid index for the
axis group (parameter
Axis-
GroupIdx
).
507
INVALID FB
ORDER
The order in which the function
blocks were called is invalid.
Program the function blocks in
the correct order.
508
CONNECTION
NOT INITIALIZED
No statements can be trans-
ferred, as the mxA interface
has not been initialized.
Initialize the mxA interface.
(
>>>
509
510
NO CONNECTION
TO KRC
TIMEOUT HEART-
BEAT FROM KRC
Connection to robot controller
interrupted:
Restore connection, then
acknowledge error:
Robot controller is switched off
Reboot the robot controller.
Submit interpreter deselected
or stopped
Restart Submit interpreter.
Bus error or I/O configuration
faulty
Check I/O configuration.
Connecting cable defective or
not correctly connected
Exchange connecting cable or
connect it correctly.
Maximum cycle time of the
Submit interpreter is too short
(only for message no. 510)
Increase the value for
MaxSub-
mitCycle
in the function block
KRC_DIAG.
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...