8 Messages
454
INVALID TOOL
NUMBER FOR
LOAD_DATA
An invalid number has been
programmed in the function
block KRC_ReadLoadData or
KRC_WriteLoadData for read-
ing or writing the load data or
supplementary load data.
Program a valid value (parame-
ter
Tool
).
(
(
>>>
455
INVALID ANALOG
IO NUMBER
An invalid value has been pro-
grammed in a function block for
the velocity.
Program a valid value (parame-
ter
Number
):
1 … 32
456
INVALID
IPO_MODE
An invalid value has been pro-
grammed in a function block for
the interpolation mode, e.g. in a
KRC_Move function block.
Program a valid value (parame-
ter
CoordinateSystem
–
COORDSYS.IPO_MODE
).
457
INVALID
CIRC_TYPE
An invalid value has been pro-
grammed in a KRC_MoveCirc
function block for the orienta-
tion control during the circular
motion.
Program a valid value (parame-
ter
CircType
).
(
458
INVALID FRAME
DATA
Invalid TOOL or BASE data
have been programmed in a
KRC_WriteToolData or
KRC_WriteBaseData function
block.
Program valid data (parameter
ToolData
or
BaseData
).
(
(
459
INVALID LOAD
DATA
Invalid load data have been
programmed in a
KRC_WriteLoadData function
block.
Program valid data.
(
>>>
460
INVALID
SOFT_END
(REVERSED)
Error writing the software limit
switches: positive software limit
switch < negative software limit
switch
Program lower values for the
negative software limit switch
than for the positive software
limit switch.
461
INVALID INTER-
RUPT STATE
Internal exceptional error
Contact KUKA Roboter GmbH.
(
>>>
462
INVALID SYS VAR
INDEX
An index for which no system
variable is stored has been
transferred in a
KRC_ReadSysVar or
KRC_WriteSysVar function
block.
Program a valid value (parame-
ter
Index
).
(
(
463
INVALID SYS VAR
VALUE
An invalid value has been pro-
grammed in a
KRC_WriteSysVar function
block for the system variable.
Program a valid value (parame-
ter
Value1 … Value10
).
(
464
SYS VAR NOT
WRITEABLE
An error occurred when writing a system variable.
The specified system variable does not exist or may not be written
in the current operating state.
465
INVALID REAL
VALUE
The programmed Real value is
invalid.
Program a valid value:
-2,147,483,500 …
+2,147,483,500
No.
Message text
Cause
Remedy
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...