KUKA.PLC mxAutomation Logix 1.0
32
INVALID BASE
NUMBER
An invalid number has been
programmed in the function
block KRC_ReadBaseData or
KRC_WriteBaseData for the
BASE coordinate system.
Specify the number of the
BASE coordinate system that is
currently being used in the
robot controller (parameter
BaseNo
).
1 … 32
An invalid number has been
programmed in a KRC_Move or
KRC_Jog function block for the
BASE coordinate system.
Specify the number of the
BASE coordinate system that is
currently being used in the
robot controller (parameter
CoordinateSystem
–
COORD-
SYS.Base
).
(
>>>
33
INVALID TOOL
NUMBER
An invalid number has been
programmed in the function
block KRC_ReadToolData or
KRC_WriteToolData for the
TOOL coordinate system.
Specify the number of the
TOOL coordinate system that is
currently being used in the
robot controller (parameter
ToolNo
).
1 … 16
An invalid number has been
programmed in a KRC_Move or
KRC_Jog function block for the
TOOL coordinate system.
Specify the number of the
TOOL coordinate system that is
currently being used in the
robot controller (parameter
CoordinateSystem
–
COORD-
SYS.Tool
).
(
>>>
34
INVALID VELOC-
ITY
An invalid value has been pro-
grammed in a function block for
the velocity.
Program a valid value (parame-
ter
Velocity
):
0 … 100%
35
INVALID ACCEL-
ERATION
An invalid value has been pro-
grammed in a function block for
the acceleration.
Program a valid value (parame-
ter
Acceleration
):
0 … 100%
36
INVALID C_PTP
An invalid approximation dis-
tance has been transferred for
a PTP motion.
Program a valid value (parame-
ter
Approximate
).
(
>>>
37
INVALID C_DIS
An invalid distance parameter
has been transferred for an
approximated motion.
38
INVALID C_VEL
An invalid velocity parameter
has been transferred for an
approximated motion.
39
INVALID C_ORI
An invalid orientation parameter
has been transferred for an
approximated motion.
40
INVALID
ORI_TYPE
An invalid value has been pro-
grammed in a KRC_Move or
KRC_Jog function block for the
orientation control of the TCP.
Program a valid value (parame-
ter
OriType
).
(
>>>
41
POSITION DATA
NOT INITIALIZED
No end position transferred
when calling a KRC_Move
function block.
Define at least 1 element of the
end position (parameter
Posi-
tion
).
(
>>>
No.
Message text
Cause
Remedy
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...