Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
7 Programming
Outputs
7.6.19
Reading TOOL data
Description
The function block KRC_ReadToolData reads the TOOL data of the robot.
Memory
Inputs
ExecuteCmd
BOOL
The statement is executed in the case of a rising edge of
the signal.
BufferMode
INT
Mode in which the statement is executed
1
: ABORTING
2
: BUFFERED
(
Parameter
Type
Description
Parameter
Type
Description
ErrorID
DINT
Error number
Busy
BOOL
TRUE = statement is currently being trans-
ferred or has already been transferred
Done
BOOL
TRUE = statement has been executed
Aborted
BOOL
TRUE = statement was aborted before it was
processed in the advance run
Error
BOOL
TRUE = error in function block
Fig. 7-20: Function block KRC_ReadToolData
Parameter
Type
Description
KRC_AxisGroup
RefArr
AXIS_GROUP_
REF_ARR
Reference to the internal structure of the axis group
Parameter
Type
Description
AxisGroupIdx
INT
Index of axis group
ExecuteCmd
BOOL
The statement is executed in the case of a ris-
ing edge of the signal.
ToolNo
INT
Number of the TOOL coordinate system
1 … 16
: TOOL_DATA[1 … 16]
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...