Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
KUKA.PLC mxAutomation Logix 1.0
54
INVALID TOOL
NUMBER FOR
LOAD_DATA
An invalid number has been
programmed in the function
block KRC_ReadLoadData or
KRC_WriteLoadData for read-
ing or writing the load data or
supplementary load data.
Program a valid value (parame-
ter
Tool
).
(
>>>
(
>>>
55
INVALID ANALOG
IO NUMBER
An invalid value has been pro-
grammed in a function block for
the analog input or output.
Program a valid value (parame-
ter
Number
):
1 … 32
56
INVALID
IPO_MODE
An invalid value has been pro-
grammed in a function block for
the interpolation mode, e.g. in a
KRC_Move function block.
Program a valid value (parame-
ter
CoordinateSystem
–
COORDSYS.IPO_MODE
).
(
>>>
57
INVALID
CIRC_TYPE
An invalid value has been pro-
grammed in a KRC_MoveCirc
function block for the orienta-
tion control during the circular
motion.
Program a valid value (parame-
ter
CircType
).
(
>>>
58
INVALID FRAME
DATA
Invalid TOOL or BASE data
have been programmed in a
KRC_WriteToolData or
KRC_WriteBaseData function
block.
Program valid data (parameter
ToolData
or
BaseData
).
(
>>>
(
>>>
59
INVALID LOAD
DATA
Invalid load data have been
programmed in a
KRC_WriteLoadData function
block.
Program valid data.
(
>>>
60
INVALID
SOFT_END
(REVERSED)
Error writing the software limit
switches: positive software limit
switch < negative software limit
switch (function block
KRC_WriteSoftEnd or
KRC_WriteSoftEndEx)
Program lower values for the
negative software limit switch
than for the positive software
limit switch.
61
INVALID INTER-
RUPT STATE
Internal exceptional error
Contact KUKA Roboter GmbH.
(
>>>
62
INVALID SYS VAR
INDEX
An index for which no system
variable is stored has been
transferred in a
KRC_ReadSysVar or
KRC_WriteSysVar function
block.
Program a valid value (parame-
ter
Index
).
(
>>>
(
>>>
63
INVALID SYS VAR
VALUE
An invalid value has been pro-
grammed in a
KRC_WriteSysVar function
block for the system variable.
Program a valid value (parame-
ter
Value1 … Value10
).
(
>>>
64
SYS VAR NOT
WRITEABLE
An error occurred when writing a system variable.
The specified system variable does not exist or may not be written
in the current operating state.
No.
Message text
Cause
Remedy
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...