Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
8 Messages
42
AXISPOSITION
DATA NOT INITIAL-
IZED
No axis position transferred
when calling a KRC_MoveAxis
function block.
Define at least 1 axis position
(parameter
AxisPosition
).
(
43
INVALID TRIGGER
DISTANCE
An invalid value has been pro-
grammed in a
KRC_SetDistanceTrigger func-
tion block for the switching
point of the trigger.
Program a valid value (parame-
ter
Distance
):
0
: Switching action at the
start point
1
: Switching action at the
end point
44
INVALID TRIGGER
IO
An invalid output has been pro-
grammed in a
KRC_SetDistanceTrigger or
KRC_SetPathTrigger function
block.
Program a valid value (parame-
ter
Output
):
1 … 2,048
45
INVALID TRIGGER
PULSE
An invalid value has been pro-
grammed in a
KRC_SetDistanceTrigger or
KRC_SetPathTrigger function
block for the length of the pulse.
Program a valid value (parame-
ter
Pulse
):
0.1 … 3.0 s
0.0 s
(No pulse active)
46
INVALID CIRC_HP
No auxiliary position transferred
when calling a KRC_MoveCirc
function block.
Define at least 1 element of the
auxiliary position (parameter
CircHP
).
(
47
INVALID INTER-
RUPT IO
The number of the digital input
to which the interrupt is
declared is invalid (function
block KRC_DeclareInterrupt).
Program a valid value (parame-
ter
Input
):
1 … 2,048
48
INVALID INTER-
RUPT PRIORITY
An invalid number was trans-
ferred when calling a
KRC_…Interrupt function block.
Program a valid value (parame-
ter
Interrupt
):
1 … 8
49
INTERRUPT NOT
DECLARED
Interrupt has not been
declared.
Declare interrupt.
(
50
INVALID INTER-
RUPT ACTION
The interrupt reaction pro-
grammed when the the inter-
rupt was declared is invalid.
Program a valid reaction
(parameter
Reaction
).
(
51
INVALID IO NUM-
BER
The number of the digital input
to which the interrupt is
declared is invalid (function
block KRC_DeclareInterrupt).
Program a valid value (parame-
ter
Input
):
1 … 2,048
52
INVALID PULSE
DURATION
An invalid value has been pro-
grammed in the function block
KRC_WriteDigitalOutput for the
length of the pulse.
Program a valid value (parame-
ter
Pulse
):
0.1 … 3.0 s
0.0 s
(No pulse active)
53
INVALID
BUFFER_MODE
An invalid
BufferMode
has
been programmed in a function
block, e.g. DIRECT mode is not
available for certain function
blocks.
Program a valid
BufferMode
.
(
No.
Message text
Cause
Remedy
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...