58 / 123
Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
KUKA.PLC mxAutomation Logix 1.0
Memory
Inputs
Outputs
7.6.29
Declaring interrupts
Description
The function block KRC_DeclareInterrupt declares an interrupt to a digital in-
put. There are 8 predefined interrupts available for this.
Syntax
GLOBAL INTERRUPT DECL 90+
Interrupt
WHEN $IN[
Input
] ==
InputValue
DO
Subprogram
Parameter
Type
Description
KRC_AxisGroup
RefArr
AXIS_GROUP_
REF_ARR
Reference to the internal structure of the axis group
Parameter
Type
Description
AxisGroupIdx
INT
Index of axis group
ExecuteCmd
BOOL
The statement is executed in the case of a rising edge of the
signal.
E1_Min …
E6_Min
REAL
Negative software limit switch of axis E1 … E6
(Unit: mm or °)
E1_Max …
E6_Max
REAL
Positive software limit switch of axis E1 … E6
(Unit: mm or °)
BufferMode
INT
Mode in which the statement is executed
0
: DIRECT
1
: ABORTING
2
: BUFFERED
(
>>>
Parameter
Type
Description
ErrorID
DINT
Error number
Busy
BOOL
TRUE = statement is currently being trans-
ferred or has already been transferred
Done
BOOL
TRUE = statement has been executed
Aborted
BOOL
TRUE = statement was aborted before it was
processed in the advance run
Error
BOOL
TRUE = error in function block
Содержание KUKA.PLC mxAutomation Logix 1.0
Страница 12: ...12 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 16: ...16 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 20: ...20 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 110: ...110 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 118: ...118 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 122: ...122 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...
Страница 123: ...123 123 Issued 13 08 2012 Version KST PLC mxAutomation Logix 1 0 V1 en PDF KUKA PLC mxAutomation Logix 1 0...