Multicheck6010
EN
- 90 -
Prospective fault current (calculated value)
Range (A)
Resolution (A)
Accuracy
0.00
÷
19.99
0.01
Consider accuracy of fault loop
resistance measurement
20.0
÷
99.9
0.1
100
÷
999
1
1.00k
÷
9.99k
10
10.0
÷
100.0k
100
Nominal voltage range
93 V
÷
134 V; 185 V
÷
266 V (45 Hz
÷
65 Hz)
6.5 Line impedance and prospective short-circuit current
Line impedance
Measuring range according to EN61557-3 is 0.25Ω
÷
1999Ω.
Zline L-L, L-N, I
psc
subfunction
Range (Ω)
Resolution (Ω)
Accuracy*
0.2
÷
9999
(0.20 ... 19.99)
0.01
(20.0 ... 99.9)
0.1
(100 ... 9999)
1
±(5 % of r 5 digits)
Prospective short-circuit current (calculated value)
Range (A)
Resolution (A)
Accuracy
0.00
÷
19.99
0.01
Consider accuracy of line resistance
measurement
20.0
÷
99.9
0.1
100
÷
999
1
1.00k
÷
9.99k
10
10.0
÷
100.0k
100
Test current (at 230 V)
3.4 A, Sine wave 50Hz (10 ms ≤ t
LOAD
≤ 15 ms)
Nominal voltage range
93 V
÷
134 V; 185 V
÷
266 V; 321V
÷
485V (45Hz
÷
65Hz)
6.6 Phase rotation
Measuring according to EN61557-7
Nominal mains voltage range
50 VAC
÷
550 VAC
Nominal frequency range
45 Hz
÷
400 Hz
Result displayed
Derecha:1-2-3 ; Izquierda: 3-2-1
Содержание Multicheck6010
Страница 1: ...Multicheck6010 Comprobador multifunción Multifunction tester Manual de usuario User s manual ...
Страница 2: ......
Страница 51: ...Multicheck6010 EN Multifunction tester ...
Страница 99: ......
Страница 100: ......