KOZI
D
IRECT
V
ENT
G
AS
S
TOVE
32
FUEL CONVERSION INSTRUCTIONS
It is recommended that a qualified service agent, technician or your local
KOZI
dealer
should conduct all conversion attempts.
Pilot Orifice
1. Using a 7/16” wrench, remove the Pilot Hood from the Pilot
Assembly.
2. Place the Quick Change Pilot Tab to the proper position (as shown
in Figure 13).
3. Replace Pilot Hood and tighten securely.
4. Test for gas leakage at all pilot connections.
14/
20
NATURAL GAS
14/
20
PROPANE
Figure 13: Quick Change Pilot Assembly Tab Position for Natural Gas (left) and
Propane (right).
BURNER ORIFICE
WARNING:
Read the following instructions to completion prior to starting the conversion.
Leakage testing must be performed at every gas connection, which has been
altered. This can be done through instrument and/or soap testing.