CONNECTING THE GAS SUPPLY
The gas connection provided with this unit is a flexible connector and is easily accessible
through the rear, side and bottom of the stove or by opening the side door panel and
reaching in through the access hole. The gas line can also be rigid pipe, if so desired. To
make the installation easier, use the flexible connector and manual shutoff valves
necessary, according to the local building codes. Insure that the minimum and maximum
inlet pressures are correct as listed below in the table of appliance specifications.
NOTE:
The manifold pressure is controlled by an internal regulator and should be
checked before firing, at the pressure test point provided. Supply
pressure should also be checked prior to firing. These test points are the
two 1/8” NPT plugged tapping located in the middle of the gas valve
assembly. The supply / inlet side is marked “IN” and is located directly
above the manifold / outlet point, labeled “OUT”.
Appliance Specifications
Burner Orifice Inlet Sizes At Altitude
Up To 4500 Ft.
Natural
Gas
#35
Propane #51
Input Rating
Natural Gas
35, 000 btu/h
Propane 33,
000
btu/h
Minimum Output Capacity With Blower Off
Natural Gas
26, 250 btu/h
Propane 24,
750
btu/h
Maximum Output Capacity With Blower On
Natural Gas
26, 950 btu/h
Propane 25,
410
btu/h
Supply Pressure
Natural Gas
Min.
7.0” w.c.
Max.
8.0”
w.c.
Propane Min.
10.5”
w.c.
Max.
13.0”
w.c.
Manifold Pressure
Natural Gas
3.5”
+/- 0.2” w.c.
Propane
10”
+/- 0.2” w.c.