62
4
© 2017 KOSTAL Solar Electric GmbH
Operation and operating the device
4.6 Operational status (LEDs)
The LEDs on the front of the device indicate the current
operational status.
LEDs on the inverter
Fig. 44: LEDs on the display of the inverter
1
"Fault" LED flashes or lights up red:
A fault has occurred. Remedial measures can be
found in the "Event codes" chapter
2
"DC" LED lit yellow:
The yellow LED signals the
active status of the inverter control unit. It lights up as
soon as the minimum input voltage (V
DCmin
) is present
at one of the DC inputs but the inverter is not yet
feeding.
"DC" LED flashes yellow:
A fault has occurred.
Remedial measures can be found in the "Event
codes" chapter
3
"AC" LED lit green:
The green LED signals the
feed-in mode of the inverter.
No LED is lit:
The device is ready for operation, but the
input voltage is too low
OR:
The device is switched off.
2
3
4
6
7
8
9
10
11
1
5