109
7
© 2017 KOSTAL Solar Electric GmbH
General information
Activating the activepower control
function in the Webserver
1.
Connect the inverter and computer with an Ethernet
cable.
2.
Launch an Internet browser.
3.
Enter the IP address of the master inverter in the
address line of the browser and confirm with
"Return".
P
The input screen for the access data opens.
4.
Enter your user name and password.
P
The Webserver opens.
5.
Select "Settings" > "Analog inputs".
P
"Analog inputs" opens.
6.
Select the function "Active power control".
7.
Click on the "Accept" button.
H
The active power control for the ripple control
receiver is active.
IMPORTANT
INFORMATION
The configuration must be carried
out on the master inverter to
which the ripple control receiver is
connected.
No adjustments are necessary on
the other inverters.
INFO
The IP address can be queried
by way of the control panel in the
"Settings" menu.
The IP address is found in the inverter
menu under “Settings/Communica-
tion/Network settings 2".
Additional entry options in the
address line of the browser:
S and the serial number of the
inverter on the type plate (example:
http://S12345FD323456)
2
3
4
6
7
8
9
10
11
1
5