FUNCTIONING
LONG PERIODS OF INACTIVITY
3-187
LONG PERIODS OF INACTIVITY
3
BEFORE A PERIOD OF INACTIVITY
3
NOTICE
q
To protect the cylinder rods when the machine is not
used, position the work equipment as shown in the
figure.
(This serves to prevent the cylinder rods from rusting).
q
Before removing the battery, stop the engine, wait at
least one minute, and afterwards turn the battery main
switch to OFF and extract the specific key.
If the machine is going to remain unused for a long period (more than one month), proceed as indicated below.
q
Clean and wash all the machine components, then store the machine indoors. If the machine is going to be
stored outdoors, choose a level surface and cover the machine with a cloth.
q
Fill the fuel tank completely, to prevent the accumulation of condensate.
q
Lubricate where necessary and change the oil.
q
Coat the exposed portion of the hydraulic cylinder piston rod with grease..
q
After turning off the engine, wait a minute, then turn the battery switch to OFF and remove it. Cover up the
battery during long periods of inactivity.
q
Lock all the control levers and pedals with the safety lever and the pedal locking device.
q
If the machine is equipped with optional equipment, move the selection valve to the "breaker and other
equipment" position.
q
To avoid the risk of corrosion, fill the cooling system with super-coolant (AF-NAC) with a density of at least
30%.
DURING A PERIOD OF INACTIVITY
3
WARNING
If it is necessary to carry out a rust-prevention treatment while the machine is kept indoors, open doors
and windows to increase ventilation and avoid poisoning by gas.
When the machine is not used, start the machine once a month following the steps below.
q
Recharge the battery and install it on the machine.
q
Insert the key into the battery main switch and turn it to ON.
q
Start the engine and make some movements with the working tools so as to cover the moving parts and all the
component surfaces with a new oil layer.
q
When operating the work equipment, remove all the grease from the hydraulic cylinder rods.
q
If the machine is fitted with conditioner, operate it for 3-5 minutes per month in order to lubricate all the parts of
the compressor. Also check the gas quantity twice a year.
WEAM014802
Содержание PC118MR-8
Страница 1: ......
Страница 2: ......
Страница 3: ...FOREWORD 11 WEAM014802...
Страница 5: ...FOREWORD FOREWORD 1 3 Storage location for the Operation and Maintenance Manual WEAM014802...
Страница 27: ...SAFETY SAFETY LABELS 2 3 LOCATION OF SAFETY LABELS 2 WEAM014802...
Страница 40: ...SAFETY LABELS SAFETY 2 16 For detail see LIFTING CAPACITIES TABLES 3 168 q Overload alarm WEAM014802...
Страница 84: ...SAFETY MAINTENANCE INFORMATION SAFETY 2 60 WEAM014802...
Страница 304: ...LUBRICATION MAINTENANCE 4 18 2 PIECE BOOM 4 Grease Filter Oil WEAM014802...
Страница 379: ...SPECIFICATIONS 15 WEAM014802...
Страница 390: ...LIFTING CAPACITIES TABLES SPECIFICATIONS 5 12 WEAM014802...
Страница 416: ...INSTALLING AND REMOVING THE ADDITIONAL COUNTERWEIGHT OPTIONAL EQUIPMENT 6 26 WEAM014802...
Страница 417: ......
Страница 418: ......