AKD EtherCAT | 5 Appendix
Index
Sub-
index
Data
Type
Float
Scale
Access PDO
map.
Description
ASCII object
35AFh
0
U32
RW
no
Sets the digital output 1 mode DOUT1.MODE
35B2h
0
U32
RW
no
Sets the digital output 2 mode DOUT2.MODE
35B4h
0
INT32
RW
no
Operating Mode
DRV.OPMODE
35B8h
0
U32
RW
no
Table number for motion task
MT.TNUM
35B9h
0
INT32
RW
no
Control for Motion Task 0
MT.CNTL
35BCh
0
INT32
RW
no
Next Task Number for Motion
Task 0
MT.MTNEXT
35BDh
0
U32
RW
no
Time to next motion task
MT.TNEXT
35C2h
0
INT32
RW
no
Select regen resistor
REGEN.REXT
35C5h
0
INT32
1:1
RO
no
Actual Following Error
PL.ERR
35C6h
0
INT32
1:1
RW
no
In-Position Window (profile
position mode)
MT.TPOSWND
35C7h
0
INT32
1:1
RW
no
Max. Following Error
PL.ERRFTHRESH
35CAh
0
INT32
RW
no
Position Resolution (Numer-
ator)
UNIT.PIN
35CBh
0
INT32
RW
no
Position Resolution (Denom-
inator)
UNIT.POUT
35D2h
0
U32
RO
no
Mechanical Position
FB1.MECHPOS
35E2h
0
U32
1:1
RW
no
Sets the current limit during
homing procedure to a mech-
anical stop
HOME.IPEAK
35EBh
0
INT32
WO
no
Save Data in EEPROM
DRV.NVSAVE
35F0h
0
INT32
WO
no
Set Reference Point
HOME.SET
35FEh
0
INT32
WO
no
Stop Motion Task
DRV.STOP
35FFh
0
U32
RW
no
Selects between disable
immediately or stop and then
disable
DRV.DISMODE
3610h
0
INT32
RO
no
Ambient Temperature
DRV.TEMPERATURES
3611h
0
INT32
RO
no
Heat Sink Temperature
DRV.TEMPERATURES
3612h
0
INT32
RO
no
Motor Temperature
MOTOR.TEMP
3617h
0
U32
1:1
RW
no
Undervoltage mode
VBUS.UVMODE
3618h
0
INT32
1:1
RO
no
Actual Velocity
VL.FB
361Ah
0
INT32
RO
no
DC-bus voltage
VBUS.VALUE
361Dh
0
U32
1000:1
RW
no
Voltage level for undervoltage
fault
VBUS.UVFTHRESH
3622h
0
INT32
1:1
RW
no
Max. Velocity
VL.LIMITP
3623h
0
INT32
1:1
RW
no
Max. Negative Velocity
VL.LIMITN
3627h
0
INT32
1:1
RW
no
Overspeed
VL.THRESH
3629h
0
INT32
1000:1
RW
no
SW1 Velocity Scaling Factor
AIN.VSCALE
3656h
0
U64
1:1
RW
no
Initial feedback position
FB1.ORIGIN
3659h
0
INT32
RW
no
Type of acceleration setpoint
for the system
UNIT.ACCROTARY
365Bh
0
INT32
RW
no
Presetting for motion task that
is processed later
MT.NUM
365Fh
0
INT32
RW
no
Systemwide Definition of Velo-
city/Speed
UNIT.VROTARY
80