5.3.53 Object 605Ah: Quick stop option code (DS402)
This object defines the action, which is taken as quick stop function.
Index
605Ah
Name
Quick stop option code
Object code
VAR
Data type
INTEGER16
Category
optional
Access
R/W
PDO mapping
not possible
Value range
1, 2, 5, 6
Default value
2
Supported codes:
Bit
Description
1
Slow down on slow down ramp and transit into Switch On Disabled
2
Slow down on quick stop ramp and transit into Switch On Disabled
5
Slow down on slow down ramp and stay in Quick Stop Active
6
Slow down on quick stop ramp and stay in Quick Stop Active
AKD EtherCAT | 5 Appendix
Kollmorgen | kdn.kollmorgen.com | October 2017