AKD EtherCAT | 5 Appendix
5.3.17 Object 1017h: Producer Heartbeat Time
The producer heartbeat time defines the cycle time of the heartbeat in ms. If it’s 0, it is not
used.
Index
1017h
Name
Producer heartbeat time
Object code
VAR
Data type
UNSIGNED16
Category
conditional;
mandatory, if guarding is not supported
Access
R/W
PDO mapping
not possible
Value range
UNSIGNED16
Default value
0
5.3.18 Object 1018h: Identity Object (DS301)
The Identity Object contains general device information.
Index
1018h
Name
Identity Object
Object code
RECORD
Data type
Identity
Category
mandatory
Subindex
0
Description
highest sub-index supported
Data type
UNSIGNED8
Category
mandatory
Access
R/O
PDO mapping
not possible
Value range
1 to 4
Default value
4
Subindex 1 is a unique number for a device manufacturer.
Subindex
1
Description
Vendor ID
Category
mandatory
Access
R/O
PDO mapping
not possible
Value range
UNSIGNED32
Default value
0x6Ah (Kollmorgen)
102