AKD EtherCAT | 5 Appendix
5.3.100 Object 60FFh: Target velocity (DS402)
The speed setpoint (target velocity) represents the setpoint for the ramp generator.
Index
60FFh
Name
target velocity, VL.CMDU
Object code
VAR
Data type
INTEGER32
Mode
pv
Access
R/W
PDO mapping
possible
Unit
increments
Value range
(-2
31
) to (2
31
-1)
Default value
—
Float scaling
1000:1
EEPROM
no
5.3.101 Object 6502h: Supported drive modes (DS402)
A drive can support more then one and several distinct modes of operation. This object gives
an overview of the implemented operating modes in the device. This object is read only.
Index
6502h
Name
supported drive modes
Object code
VAR
Data type
UNSIGNED32
Category
optional
Access
R/O
PDO mapping
not possible
Value range
UNSIGNED32
Default value
0xE5 (csp ip hm pv pp)
31
16
15
11
10
9
8
7
6
5
4
3
2
1
0
manufacturer
specific
reserved
cstca cst csv csp ip
hm reserved tq pv vl
pp
MSB