Chapter 1 Installation
CVS-875D/877D
1-76
0092607072-01
7) Press [ ] of .
The setup box of [GPS Initialize] will be displayed.
8) Select [Yes] with
[▲] and [▼] keys.
9) Press .
The massage box of [It is processing
Please wait for a while] will be displayed.
10) Once initialization is completed, the message box disappears and the display
returns to the normal screen.
These steps complete the setup as follows:
The baud rate of NMEA2 (J3) of CVS-875D/877D is set to 38400bps.
The baud rate of Port A of V102 GPS Compass is set to 38400bps, and Heaving data
output is generated.
The baud rate of Port C of V102 GPS Compass is set to 38400bps, and GPS compass
data output is generated.
Caution: It takes approximately 5 minutes until the heaving data of Hemisphere
V102/V104s/V200s GPS Compass / ComNav Vector G1 GPS Satellite
Compass stabilizes after the start up. During the time, heaving correction
may not be done correctly, however, this is not breakdown of the
equipment.
It is processing
Please wait for a while.