Chapter 1 Installation
CVS-875D/877D
1-36
0092607072-01
2) Connect the transducer and the junction box (JB-34).
Cable of the transducer is configured as shown in Fig. 1.32.
Refer to Fig. 1.33, connect the cable to the junction box (JB-34).
Fig. 1.32 Details of transducer cable
Fig. 1.33 Connection between junction box and transducer
NC
Water Temp. sensor
Low frequency
High frequency
XID-adaptive TD cable
TDM-052A
TDM-062A
TDM-083
Shield
White
Brown
Orange
Violet
Shield
Black
(Black/White)
Yellow
(Blue/White)
Shield
Black
Blue
Shield
XID
Blue
White
Green
Red
Orange
Black
Shield
Shield
Black
White
Shield
Green
Red
White
Brown
Orange
Violet
Shield (in)
Shield (out)
Shield
Black (Black/White)
Yellow (Blue/White)
Shield
Black
Blue
CW-844-3M
To J6
CW-836-3M
To J7
XID-adaptive TD
TDM-052A
TDM-062A
TDM-083