![Koden CVS-875D Скачать руководство пользователя страница 115](http://html.mh-extra.com/html/koden/cvs-875d/cvs-875d_installation-manual_1984764115.webp)
CVS-875D/877D
Chapter 3 Maintenance
0092607072-01
3-1
Chapter 3 Maintenance
3.1 Inspection
The daily maintenance and inspection extend the life of equipment. To keep the equipment
always in the best conditions, implement the periodical inspection shown in the table below.
Item
Inspection item
CVS-875D
Connectors at the rear of
the Display unit
CVS-877D
Connectors at the rear of
Processor unit
Check the looseness
Wiring of cables
Check the wiring of cables connecting the equipment and the
damage of cable
CVS-875D
Grounding of Display unit
CVS-877D
Grounding of Processor
unit
Scrape the rust off the ground terminal and keep good contact.
3.2 Cleaning
3.2.1 Display unit of CVS-875D
Contamination on the screen may cause faint images. For cleaning the screen, wipe it with
soft and clean cloth dipped in diluted neutral detergent. Pay full attention as the screen gets
scratched easily. No solvent such as thinner shall be used.
For cleaning the chassis, do not use solvent such as thinner or alcohol. Painting on the
surface and characters at the Operation unit may be dissolved. After wiping with soft and
clean cloth dipped with diluted neutral detergent, wipe away with dry soft and clean cloth.
Caution
The display screen has a special coating. Do not use a solvent such
as paint thinner, acetone, alcohol, and benzene, etc.
Strong rubbing may cause scratch.
Содержание CVS-875D
Страница 1: ......
Страница 2: ......
Страница 18: ...Dimensions CVS 875D 877D xvi 0092607072 01 Dimensions CVS 875D Unit mm inch ...
Страница 19: ...CVS 875D 877D Dimensions 0092607072 01 xvii CVS 877D Unit mm inch ...
Страница 20: ...Dimensions CVS 875D 877D xviii 0092607072 01 Operation unit of CVS 875D 877D Unit mm inch ...
Страница 108: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 122: ......