![Koden CVS-875D Скачать руководство пользователя страница 81](http://html.mh-extra.com/html/koden/cvs-875d/cvs-875d_installation-manual_1984764081.webp)
CVS-875D/877D
Chapter 1 Installation
0092607072-01
1-59
1.7 Connection of Hemisphere V102/V104s/V200s GPS Compass /
ComNav Vector G1 GPS Satellite Compass
This is to describe the connection of Hemisphere V102/V104s/V200s GPS Compass /
ComNav Vector G1 GPS Satellite Compass used as GPS compass and Heaving sensor.
Refer to the installation manual of the Hemisphere V102/V104s/V200s GPS Compass /
ComNav Vector G1 GPS Satellite Compass for details of installation.
1.7.1 Connection of Hemisphere V102/V104s/V200s GPS Compass / ComNav
Vector G1 GPS Satellite Compass
Connect CW-376-5M by soldering with the cable of Hemisphere V102 GPS Compass /
ComNav Vector G1 GPS Satellite Compass. (Hereafter referred to as
“V102 GPS Compass”)
Please prepare two CW-376-5M when connecting with Radar as GPS compass.
1) The terminal of the cables of V102 GPS Compass is not processed, and 8 lead wires and
1 shield wire are open. Brown and blue lead wires are connected to TX/RX of Port A, white
and green lead wires are connected to TX/RX of Port C, black and red lead wires are
connected to +/- of power supply, and yellow lead wire is connected with earth. Orange
lead wire and shield wire are unconnected.
Refer to the
“Connection table of V102 GPS Compass”
, and solder CW-376-5M with
Port A and power supply of cable of Hemisphere V102 GPS Compass. Please solder
another CW-376-5M with Port C, when connecting with Radar as GPS compass. Please
branch yellow wire (GND) of the cable of V102 GPS Compass into four, two of which shall
be soldered with each black (RX-) and red (TX-) of CW-376-5M. After soldering is
completed, be sure to process the connected part by self-adhesive tape etc. to be water
resistant and insulated.
Fig. 1.57 Connection of V102 GPS Compass
CW-376-5M
Cable of V102 GPS Compass
Blue and shield
White
Orange
Green
Red
Black
Red
Black
White
Orange
Black
Brown
Blue
Red
Yellow
Yellow
Yellow
Yellow
Green
White
Orange
Shield
To NMEA terminal of Radar
CW-376-5M
Solder
e
d
To J3 connector of
CVS-875D/877D
Port A/Power
Port C
Yellow wire is branched into 4.
Unconnected
Solder
e
d
Содержание CVS-875D
Страница 1: ......
Страница 2: ......
Страница 18: ...Dimensions CVS 875D 877D xvi 0092607072 01 Dimensions CVS 875D Unit mm inch ...
Страница 19: ...CVS 875D 877D Dimensions 0092607072 01 xvii CVS 877D Unit mm inch ...
Страница 20: ...Dimensions CVS 875D 877D xviii 0092607072 01 Operation unit of CVS 875D 877D Unit mm inch ...
Страница 108: ... This page intentionally left blank ...
Страница 114: ... This page intentionally left blank ...
Страница 122: ......