CVS-875D/877D
Chapter 1 Installation
0092607072-01
1-53
In the case of connection of dual frequency type TD with diplexer via the junction box
(JB-34):
1) Connect the CW-836-3M to the junction box (JB-34).
2) Connect the CW-836-3M to J7 connector of CVS-875D/877D.
Fig. 1.49
Connection between CVS-875D/877D and junction box
Connection list of junction box (JB-34)
CVS-875D/877D
Cable
CW-836-3M
Junction Box
(
JB-34
)
Connector
Color of cable
Pin No.
Signal name
J7
1
Red
1
TD1H (High frequency1)
2
3
Shield
3
GND
4
Green
4
TD2H (High frequency2)
5
6
-
2
White
7
TD1L (Low frequency1)
8
3
Shield
9
GND
5
Black
10
TD2L (Low frequency2)
11
12
13
14
15
16
CW-836-3M
To J7 of CVS-875D/877D
Black
Shield
White
Green
Shield
Red