Owners Manual Ecos
aire
®
CM Series Precision Air Conditioner
Ecos
aire
®
July 2007 89
Data subject to change without notice.
HOW TO INSTALL THE REPLACEMENT CYLINDER
1. Reverse procedure should be followed to install the new cylinder.
The branch-circuit disconnect is to be left
open until the cylinder is completely installed and reconnected.
2. Ensure that the cylinder is secured properly by the re-usuable tie wrap and mounting brackets within the unit.
3. The cylinder plug wires are color-coded in accordance with the colored dots beside the electrode pins on top of
the cylinder. This color-coding
MUST
be adhered to when replacing cylinder plugs on pins.
4. With cylinders having
six primary voltage cylinder plugs
, it should be noted that there are
two of each color
.
5. Care
MUST
be taken so that the cylinder
leads of the same color
are always
directly opposite each other
as indicated by the dot formation on the top of the cylinder.
6. The white cylinder plug on all units is for the sensor electrode which
always
goes on the single pin surrounded
by a plastic shoulder.
7. Ensure that cylinder plugs fit snugly on the pins.
8. If cylinder plugs become loose, it is best to obtain a new replacement plug.
EXTENDED SHUTDOWN
Before disconnecting power to the humidifier for a period of extended shutdown,
ALWAYS DRAIN
the cylinder
first. Otherwise, the electrodes are subject to harmful corrosion which drastically shortens cylinder life.
DO NOT
leave the switch in the
DRAIN
position indefinitely as the drain coil could burn out. Leave the switch in the
OFF
position and “open” the main external fused disconnect to stop power to the humidifier. Close the shut off valve in
the water supply line feeding the humidifier.
Humidifier Maintenance Operation