e) Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the supply line shut-off valve and the cooktop. Include
gas fittings and joints in the cooktop if connections were disturbed during
installation. Check for leaks!. Bubbles appearing around fittings and
connections will indicate a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply line gas shut off
valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
f) Remove shipping polystyrene from all cooktop burners. This is to hold the
burners in place on the burner base for shipping purposes only.
GAS CONVERSION
All cooktops are equipped with both Natural Gas and LP Gas The unit model
number plate states which gas it was adjusted for at the factory. To convert
the unit to either Natural gas or LP gas will require switching burner injectors
and burner low setting adjustment.
GAS BURNER INJECTOR CONVERSION
To switch injectors, it is enough to unscrew fixed injector using a proper
7mm Hex. key tool and replace it with new injector for new gas setting.
For proper injector size, follow Cooktop Technical Data chart and fig. 4.
SERVICE – PARTS INFORMATION
When your cooktop requires service or replacement parts, contact your
dealer or authorised service agency. Please give the complete model and
serial number of the cooktop which is located on the cooktop model number
plate.
LOW SETTING VALVE ADJUSTMENT
The LOW setting should produce a stable flame when turning the knob from
HIGH to LOW. The flame should be 0.32 cm or lower and must be stable on
all ports on LOW setting.