5
4.Conversion Details
The appliance is convertible between natural Gas & LPG.
Procedure
1. Turn off gas supply to appliance.
2. Disconnect appliance from electrical power.
3. Remove the trivets and the burner cap assemblies. Replace the factory fitted NG
injectors, as supplied (see Table1).
4. Unscrew the hex nut from the regulator and tighten (or loosen) the nut threaded to
obtain the desired pressure. The pressure can be controlled on the test point on the
regulator itself.
5. Turn on the gas supply and at each new connection check for leaks using soapy
water: each hotplate valve should be turned on, one at time, and the injector hole
blanked off for several seconds.
6. The operation of the regulator can be confirmed by connecting a manometer to the
pressure test point located on the side of the regulator body adjacent to the outlet.
With the appliance operating check the outlet pressure
•
When all burners of the appliance are operating at maximum.
•
When the smallest burner of the appliance is operating at minimum.
Under these conditions the outlet pressure should not vary from the nominal outlet
pressure of 2.75kPa by more than ±0.52kPa.
7. If the regulator appears to not be performing satisfactorily the check the following
points.
•
If the outlet pressure is consistently to low then the inlet pressure may be too
low and adjustment of an upstream regulator may be needed, or an
upstream regulator or valve with insufficient flow capacity may be supply line.
If this is suspected then may be necessary to repeat the checks whilst
measuring both the inlet and outlet pressure to determine if the inlet pressure
is in the range 2.75 - 7.00kPa.
•
Check that the regulator has been fitted to the gas supply line in the correct
orientation, the arrow on the base of the body indicates the direction of gas
flow.
Once these checks have been completed, if the regulator still fails to perform in a
satisfactory manner it should be replaced.
8. One by one, turn the knobs to minimum and screw in the by-pass screw (accessible
when the knob is removed) until a small stable flame results. Turn the knob to
maximum and the back to minimum to ensure that correct minimum is maintained.
9. Attach the LPG sticker to the hop, near the gas supply inlet. Cover the natural Gas
label that is factory fitted.