5-7
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or electrical shock.
DOOR SWITCH
Refer to page 4-4 for the procedure for servic-
ing a door switch.
1.
Unplug the refrigerator or disconnect the
power.
2.
Disconnect one of the wires going to the
door switch.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test probes to the
N.O. and COM door switch terminals.
5.
The meter should indicate an open circuit
(infinite).
6.
Press the door switch actuator button and
the meter should indicate continuity (0
Ω
).
7.
Touch the ohmmeter test probes to the
N.C. and COM door switch terminals.
8.
The meter should indicate continuity (0
Ω
).
NOTE: The door switches are normally-
closed.
9.
Press the door switch actuator button and
the meter should indicate an open circuit
(infinite).
WATER VALVE SOLENOID
Refer to page 4-22 for the procedure for servic-
ing the water valve.
1.
Unplug the refrigerator or disconnect the
power.
2.
Disconnect the wire connectors from the
water valve solenoid terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test probes to the
terminals of the ice maker solenoid. The
ohmmeter should indicate approximately
160 to 170
Ω
.
5.
Touch the ohmmeter test probes to the
terminals of the water dispenser solenoid.
The ohmmeter should indicate approxi-
mately 330 to 355
Ω
.
Ice Maker Solenoid (1/4
″
Outlet)
Water Dispenser Solenoid (5/16
″
Outlet)
Содержание KSSC36FKB00
Страница 62: ...5 8 NOTES ...
Страница 66: ...6 4 NOTES ...
Страница 67: ...7 1 WIRING DIAGRAMS STRIP CIRCUITS WIRING DIAGRAM BOTTOM MOUNT P5 P7 P6 P2 P3 P4 ...
Страница 68: ...7 2 WIRING DIAGRAM SIDE BY SIDE MODELS P5 P7 P6 P2 P3 P4 OPTIONAL DISPENSER MODELS ONLY ...
Страница 72: ...7 6 NOTES ...
Страница 73: ...7 7 NOTES ...
Страница 74: ...7 8 NOTES ...
Страница 76: ......