7. MAINTENANCE
The purpose of the maintenance and adjustment schedule is to keep the generator in
the best operating condition.
Shut off the engine before performing any maintenance.
If the engine must be run, make sure the area is well
ventilated. The exhaust contains poisonous carbon
monoxide gas.
Use genuine our parts or their equivalent. The use of
replacement parts which are not of equivalent quality
may damage the generator.
7.1 Inspect or service as scheduled in the table below.
Items
Daily
First
month or
10hrs
Every 3
month or
50hrs
Every 6
month or
100hrs
Every
year or
300hrs
Interval(1)
Engine oil
Check
○
Replace
○
○
Air cleaner
Check
○
Clean
○(2)
Spark plug
Clean-adjust
○
Spark arrester
Clean
○
Valve clearance
Clean-adjust
○
(3)
Fuel tank and filter
Clean
○
(3)
Oil pipe
Check
Every two years (replace if necessary(3))
Note:
The items marked by (1) means regular service interval.
The items marked by (2) shall be serviced more frequently when used in dusty
areas.
The items marked by (3) shall be serviced by authorized Kipor dealer, unless you
have proper tools and are mechanically proficient. Refer to the operation
manuals.
Содержание Sinemaster IG2000i
Страница 1: ...1...
Страница 8: ...7 3 COMPONENT IDENTIFICATION...
Страница 27: ...26...
Страница 46: ...45 13 WIRING DIAGRAM IG2000i Wiring Diagram...
Страница 51: ...50 Intake System and Carburetor Exhaust System...
Страница 53: ......
Страница 54: ......
Страница 60: ...4 2 COMPONENT IDENTIFICATION 2 1 Outline drawing Figure 1 Figure 1 Outline drawing...
Страница 61: ...5 2 2 Inlet System Figure 2 2 3 CARB Evaporative Control System Figure 3...
Страница 62: ...6 2 4 Carbon Canister Location CARB only Figure 4 2 5 Control panel See figure 5 Figure 5...
Страница 85: ...29 Appliance does not operate...
Страница 87: ...31 11 Electrical principle diagram Figure 32 Electrical principle diagram...