1. CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete draining.
■
Make sure to turn the engine switch and the fuel cap vent lever OFF before
draining.
1. Loosen the cover screw and remove the left side maintenance cover.
2. Remove the oil filler cap.
3. Drain dirty oil into a container thoroughly. See note below concerning proper
disposal.
4. Refill with the recommended oil, and check the oil level.
5. Reinstall the left side maintenance cover and tighten the cover screw securely.
Engine oil capacity: 0.42 qt. (0.4L)
■
Please dispose of used motor oil in a manner that is compatible with the
environment and local disposal regulations. Do not throw it in the trash or pour it
on the ground.