Service Port Software
2.3 Automatic ventilation
When this function is activated, a time in minutes can be
entered following which the drive closes again in vent
switch operation. If vent switch operation is interrupted
this function is deactivated and is not reactivated until
opened again in vent switch button operation.
Note
: This function is deactivated when supplied.
2.4 Switch functions
The vent switch inputs can be set to two different modes.
One option activates push button operation so that OPEN
or CLOSE is operated until the stop button (OPEN and
CLOSED simultaneously) is pressed. The other option
switches to deadman operation so that activation lasts
only as long as the OPEN or CLOSE switch is activated.
Default values:
Vent switch
switch operation so that the normal vent
switches can be used.
Vent switch Superior
deadman, so that a key switch
can be used for activation, for example.
2.5 Pole change time
The pole change time determines the pause time when
there is a change of polarity in the motor output current.
2.6 Activation time
The activation time determines the time after which the
windows will be completely opened or closed (by the
drives). This can be used to activate and deactivate the
activation time. When it is activated the time can be
entered in seconds; the default value is 180 seconds
(3 minutes). It should be noted that in some modes the
activation time is required. There is a note to that effect for
each mode where this applies.