background image

H6

GUARANTEE TERMS AND CONDITIONS

This guarantee applies only to products manufactured 
by Kingspan Environmental and its associated brands 
(hereafter the term ‘product’ refers to 

U

LTRASTEEL PLUS).

Kingspan Envirnmental guarantees to the homeowner that for 
a period of 2 years from the date of commissioning 
or legal completion if new build, that the products and 
associated components installed will - Conform to Kingspan 
Environmental specification; and be free from defects in 
materials and workmanship, subject to the conditions set out 
below.

Please note:

 this guarantee excludes all pipework and 

connections and excludes any ancillary equipment as may be 
connected to the product. (Ex: descaling equipment, water 
softeners)

The guarantee is extended to a total of 25 years for the 
stainless steel inner vessel in domestic properties.

This guarantee means that Kingspan Environmental will take 
responsibility for the cost of guarantee repair of a product by 
an approved Kingspan Environmental Service Engineer, so 
that the product shall conform to Kingspan Environmental 
specification. 

Kingspan  Environmental  reserves  the  right,  at  it’s  discretion 
to replace a product or major component where it considers it 
to be beyond economical repair.

In the event of a breakdown during the guarantee period 
please call our Customer Service Department on: 

0845 260 7260 - UK

Guarantee repair is free of charge to you for any parts and 
labour, providing all the guarantee conditions have been met.

GUARANTEE TERMS & CONDITIONS

Please read the following conditions before registering your 
product and before seeking any guarantee service support

 

IMPORTANT:  Kingspan Environmental guarantee is 
subject to the home owner registering with the Kingspan 
Environmental Customer Service Department within 30 days 
of commissioning / occupation if new build to confirm: 

• Product Make / Model
• Details installation (can be found in Benchmark Log Book
left by installer)
Please complete the registration card provided and return
to:
Customer Service Department, Kingspan Environmental,
Tadman Street, Wakefield, WF1 5QU, UK
or register the product on-line at
www.kingspanenviro.com/guarantee
If you do not register the Product then Kingspan
Environmental Guarantee is limited to twelve months from
the date of commissioning.
The product must be maintained by a competent person*

within 12 months after commissioning, and thereafter at 
12 monthly intervals. Kingspan Environmental reserves 
the right to seek evidence of this maintenance to our 
reasonable satisfaction before approving any guarantee 
servicing / repairs. This may include evidence of completed 
BenchmarkTM log book and service agreement / invoice.
Annual Services are available from the Customer Service/ 
Technical Support team.
*A competent person is a business that has been adjudged
by an accredited body**  to be sufficiently competent to
self-certify that its work complies with Document (G) Part 3
of the Building Regulations of England and Wales
*May Include SEI registered installers and/or FAS trained
plumbers who have completed the renewables technology
module
** An example of which is BPEC
Any exchanged component will become the legal property of
Kingspan Environmental.
This guarantee is valid provided that:
• The product has been installed by a competent installer
and as per the instructions contained in the installation
manual and all relevant Codes of Practice and Regulations in
force at the time of installation.
• Any disinfection has been carried out in accordance with
BS 6700.
• The product  has not been modified in any way.
• The system is fed from domestic mains water supply
complience with water regulations 2000
• The product has only been used for the storage of
wholesome water (max. 250mg/l chloride – for hard water
areas, Kingspan recommend the use of an electrolytic scale
reducer)
• Any 3rd party labour charges associated with replacing
the unit or any of its components have been authorised in
advance by the Customer Service/ Technical Support team.
• It has only been used for the storage of potable water.
• The product  has not been subjected to frost, nor has it
been tampered with or been subjected to misuse or neglect.
• No factory fitted parts have been removed for
unauthorised repair or replacement.
• The BenchmarkTM Commissioning Checklist and Service
Record included with this product Installation Manual have
been  completed.
• Regular maintenance has been carried out by a competent
person in accordance with the requirements set out in the

maintenance section of the installation manual.

• The owner or installer has registered the product on-
line at www.kingspanhws.com/warranty within 30 days of
purchase. Failure to do so may result in a reduced warranty
period.
• Evidence of purchase and date of supply must be submitted
upon making a claim.
• Any replacement parts used should be authorised Kingspan
Environmental spare parts.

KINGSPAN ALBION
RELIABLE HOT WATER CYLINDERS

Kingspan have a policy of continuous product development and may introduce product modifications from time to time.

As a consequence details given in this brochure are subject to alteration without notice. E&OE.

Содержание AUXD120

Страница 1: ...JANUARY 2017 PART NO 024458 ULTRASTEEL PLUS INSTALLATION AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...be checked to ensure it can meet these requirements If necessary consult the local water company regarding the likely pressure and ow rate availability If measuring the water pressure note that a high...

Страница 3: ...centralheating co uk for more information IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation Unvented cylinders are a controlled service as de ned in the latest edi...

Страница 4: ...direct Models Immersion heater Spare Part No 021533 High Limit thermostat Spare Part No STATHIGHALT Two port valve Spare Part No VALVE2PORTH Acetal tundish 15 x 22 mm Spare Part No TUNDPL15ALT Tempera...

Страница 5: ...80 litre sizes there is no dedicated secondary return boss and the secondary return circuit should be tee d into the cold feed pipe just above the drain elbow SCHEMATIC DIAGRAM Access for maintenance...

Страница 6: ...not have to be drained down in order to service the inlet control set Ensure that the arrow points in the direction of the water ow Turn to test Cold Mains In Balanced Cold Connection Outlet to Cylin...

Страница 7: ...L PLUS can be used with secondary circulation An appropriate WRAS approved bronze circulator should be used in conjunction with a non return valve to prevent back ow On large secondary circulation sys...

Страница 8: ...he tundish should be located such that any discharge is visible In addition where discharges from safety devices may not be apparent e g people with impaired vision or mobility consideration should be...

Страница 9: ...above external surfaces such as car parks hard standings grassed areas etc are acceptable providing that where children play or otherwise come into contact with discharges a wire cage or similar guard...

Страница 10: ...989 NF L D 35 2832 AUXD210 209 1557 550 184 1087 244 832 1055 1022 L D 34 2876 AUXD250 247 1802 550 184 1332 244 972 1300 1267 XL D 36 4548 AUXD300 297 2072 550 184 1584 244 1123 1552 1519 XL D 36 456...

Страница 11: ...N180 27 16 88 1 AUXN210 31 17 08 1 AUXN250 33 20 31 2 AUXN300 42 19 61 2 Boss centre from oor ErP Code Capacity Ltrs Height mm Dia mm A mm B mm C1 mm C2 mm D mm E mm F mm ErP Rating Standing Loss W AU...

Страница 12: ...temperature high limit cut out provided Iinto dry stat pocket G2 to ensure the heat input to the solar coil is interrupted if the cylinder overheats Some method to prevent thermosyphoning must also b...

Страница 13: ...umbered accordingly Where an alternative is supplied connect as per manufacturer s instructions 0 3040 65 963 4HPU Z Z WWS KV ISL WVSL M ZLK ZW Y HTW 3 5 3 6 9 A65 3 3 6 9 A65 3 3 5 7 47 0 3040 65 963...

Страница 14: ...3T 2T 1T N Danfoss TP5000 L E 1 2 3 2B 4B N 9B E DHW ZONE BLUE BR BL GR OR G Y 2B 5B N 9B E HTG ZONE 1 RED BR BL GR OR G Y THERMOSTAT 7B COMMON 8B 2 4B 1 PUMP CONNECTOR BL BR G Y N 3B E E 15B 2B 6B N...

Страница 15: ...robes will inserted into the thermostat pockets on the immersion heater The immersion heater thermostat probes should alway be inserted in the upper thermostat pocket on the immersion heater and the p...

Страница 16: ...ing Pressure 8 0 Bar Opening Pressure of T P Valve 10 0 Bar Opening Temperature of T P Valve 90o C Maximum Pressure on Primary Circuit Indirect Solar Coil 3 5 Bar Element Rating 3kW 240 V Fuse Require...

Страница 17: ...N A N A N A N A N A D XL 36 4548 AUXD300 55 355 297 N A N A N A N A N A D XL 36 4567 ULTRASTEEL PLUS INDIRECT AUXN120 35 155 119 N A 3 3 0 67 N A N A B 49 AUXN150 40 190 149 N A 3 77 0 77 N A N A B 5...

Страница 18: ...sion heater and the temperature and pressure relief valve Before lling open the hot tap furthest away from the ULTRASTEEL PLUS to let air out Open the cold main isolation valve and allow the unit to l...

Страница 19: ...inder With cylinder cold check pressure in cylinder If this is the same as the incoming mains pressure then you are getting backfeed Install a balanced cold supply see page 6 Follow recharge steps on...

Страница 20: ...r is hot turn the boiler and or the immersion heater off Do not turn off the water until the discharge runs cool The discharge may also stop CALL OUT A COMPETENT PLUMBER TO SERVICE THE UNIT Tell them...

Страница 21: ...rol set d voume is now recharged d W Z Both immersion heater control and boiler heat control thermostats should have been set during is required the the thermostat cover will need to be removed K EKd...

Страница 22: ...he unit from the cold mains Attach a hose to the draining tap ensuring that it reaches to a level below the unit this will ensure an ef cient syphon is set up and the maximum amount of water is draine...

Страница 23: ...e back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation The installer is legally...

Страница 24: ...pressure relief valve and expansion valve been tted and discharge tested Yes No The tundish and discharge pipework have been connected and terminated to Part G of the Building Regulations Yes Are all...

Страница 25: ...mments Signature SERVICE 3 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 4 Date Engineer Name Company Name Telephone Number Comments Signature SERVICE 5 Date Engineer Nam...

Страница 26: ...seek evidence of this maintenance to our reasonable satisfaction before approving any guarantee servicing repairs This may include evidence of completed BenchmarkTM log book and service agreement invo...

Страница 27: ...ufacturer shall be responsible for any consequential damage howsoever caused The effects of scale build up or the effects of corrosion Any consequential losses caused by the failure or malfunction of...

Страница 28: ...ild Date To be completed by the home owner Please use this card to register within 30 days of commissioning occupation if new build to bene t from the Kingspan Environmental 2 year guarantee By comple...

Отзывы: