background image

4000305-14

WARNING: If the information in these 
instructions is not followed exactly, a 

fi

 re 

or explosion may result causing property 
damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light the appliance.
• Do not touch any electrical switch; do not 

use any phone in your building.

• Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas 
supplier’s instructions.

• If you cannot reach your gas supplier, call 

the 

fi

 re department.

This appliance is only for use with the type 
of gas indicated on the rating plate. This 
appliance is not convertible for use with 
other gases, unless a certi

fi

 ed kit is used.

This appliance is a domestic room-heating 
appliance. It must not be used for any other 
purposes such as drying clothes, etc.

This appliance is suitable for installation in a 
bedroom or bed sitting room.

Manufactured by

MILES INDUSTRIES LTD.

British Columbia, Canada

www.miles

fi

 replaces.com

Installation & Operating Instructions

Do not store or use gasoline or other 

fl

 ammable vapors and liquids in the vicinity 

of this or any other appliance.

Installation and service must be performed 
by a quali

fi

 ed installer, service agency or the 

gas supplier.

This appliance may be installed in an 
after-market permanently located, 
manufactured (mobile) home where not 
prohibited by local codes.

Models 530XAN/XAP (logs)

Models 530XCN/XCP (coals)

Direct Vent Gas Fireplace Heater

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Massachusetts: The piping and 

fi

 nal 

gas connection must be performed by a 
licensed plumber or gas 

fi

 tter in the State of 

Massachusetts. Also, see Carbon Monoxide 
Detector requirements under “Safety and 
Warning Information” on page 5.

This manual contains instructions to install the

 ENGINE ONLY. 

A front trim kit is

 

REQUIRED 

to install the engine as it affects the framing cavity and position of the 

engine. 

Refer to the manual supplied with the front for framing and 

fi

 nishing.

Please read this manual BEFORE installing and operating this appliance.

©2007, Miles Industries Ltd. All rights reserved.

Содержание 530XAN/XAP

Страница 1: ...Operating Instructions Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified inst...

Страница 2: ...hould you encounter an operational problem call your dealer immediately Do not try to repair the unit as you may cause an injury or damage the fireplace The information contained in this installation...

Страница 3: ...onfigurations 13 Vertical Termination Installations 15 Appliance Preparation 17 Air Restrictors Installation 20 Remote Control Installation 21 Gas Supply Installation 22 Aeration Setting Check 23 Cera...

Страница 4: ...llation manual NO OTHER vent system or components MAY BE USED This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate sol...

Страница 5: ...uipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed on the next adjacent floor level b In the event that the requi...

Страница 6: ...side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the man...

Страница 7: ...30X engine is available in either natural gas or propane gas and comes equipped with either a simulated log or coal fuel bed in either fuel A pebble set is also offered as an optional feature See Opti...

Страница 8: ...pressure must be between the limits shown in the Ratings table on the previous page The supply connection is 3 8 NPT female The opening for the gas supply line is at the rear left corner of the applia...

Страница 9: ...o prevent condensation on window 12 30 D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet 60 cm from the center line of the terminal 18 46 E Cl...

Страница 10: ...ard may be required if terminating within 7 0 of grade or where accessible In Corner No Vertical Rise Maximum 1 x 45 elbow allowed Maximum 18 horizontal pipe length Terminal guard may be required if t...

Страница 11: ...es 32 33 for allowable components 14 36 cm max combustible wall 530 engine Top Outlet w Vertical Rise Horizontal Termination See Conversion to Top Outlet for Solid Direct Vent Co axial Piping in Appli...

Страница 12: ...rough the outer tube and the appliance collar with 6 screws Make sure the drill does not penetrate the inner pipe Secure the vent unit or 817VAK to the outer collar with two 6 thread cutting screws su...

Страница 13: ...depending on the particular installation 1 5 16 33 mm min clearance to combustible materials all round 40 12 2 m max Total offset 4 6 137 cm max Ceiling firestop Roof flashing Approved vertical termi...

Страница 14: ...ey systems no combustible construction The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance Flashing 2 x 3 liners 24 1 2 3 min bend radius Co linear ad...

Страница 15: ...ce the appliance in its proper location Drop a plumb from the ceiling to the center of the appliance vent opening Mark the position on the ceiling Drill a small hole at the marked position Determine t...

Страница 16: ...s on to the appliance Drop the 3 dia flexible liners into the chimney from outside Fit the liners to the co linear adapter paying attention to inlet and exhaust and move the appliance to its proper po...

Страница 17: ...end of the burner Push in the lighting knob and turn counter clockwise through the IGN position to PILOT A spark should flash across from the pilot electrode to the pilot burner shield Window Removal...

Страница 18: ...r vent collar and seal by unscrewing 8 screws To make sure that the collars are axially aligned fit the adapter 817VAK over the outer vent collar Position the inner collar and seal vertically inside t...

Страница 19: ...ter to the outer collar with two 6 thread cutting screws supplied 1 2 3 1 2 3 4 5 Co linear Conversion using Valor 556CLA Co linear Adapter Note Instructions may vary as 556CLA may be installed on Top...

Страница 20: ...e restrictors remove the center screws from the rear ports and fit the restrictors using these screws To set the restrictors at maximum port opening slacken the bottom screws in the ports slide the re...

Страница 21: ...wires are pointing up and slot in the board is in line with the tab on the wiring harness plug Connect wires as shown below Please note that the L connectors are different sizes the smaller one fits...

Страница 22: ...s The supply line should include a manual shut off valve and union to allow the appliance to be disconnected for servicing Pressure test the supply line for leaks The appliance and its individual shut...

Страница 23: ...n in this manual for adjustment details The shutter setting is very critical A change of 1 64 can make a substantial difference to the performance Ceramic Walls Installation The 530 engine is provided...

Страница 24: ...log Locate the left side log on the ceramic pin on the left hand side of the base log Rest the narrow nose of this log on the projection at the front center of the base log ensure that the narrow nose...

Страница 25: ...the right front coal behind the metal lip at the front of the firebox Its left side should rest over the projection on the left front coal The center right coal has letter R embossed underneath Place...

Страница 26: ...liance and the remote control See the Lighting Instructions on page 30 of this manual for full details Aeration adjustment As described on page 23 the burner aeration is adjustable For the vast majori...

Страница 27: ...d damage See page 17 To refit the window place it centrally against the firebox while resting it on the support at the bottom of the firebox Pull the clamping bars forward and rotate inwards to secure...

Страница 28: ...ts the minutes Set the time Note You must start setting the time while the F is flashing If it stops flashing go back to 1 The display shows C 24 hour or F 12 hour To change the temperature hour displ...

Страница 29: ...P1 appears and flashes Let go While flashing push the buttons hour and minutes to set the time at which you want your fireplace to turn on in the morning Press the TIMER button and hold it until P1 a...

Страница 30: ...2 Set the flame adjustment knob as far clockwise as possible 3 Turn the gas control knob clockwise to OFF NOTE The knob cannot be turned from PILOT to OFF unless it is pushed in partially Do not force...

Страница 31: ...rofitted at a later date Bedroom Remote Kit 562BRK Automatic shut off remote control kit for bedroom installation Circulating Fan Kit 555CFK Having variable speed and temperature control it is designe...

Страница 32: ...Snorkel 14 Rise 982 4DT ST14 Snorkel 36 Rise 981 4DT ST36 Vent Adapters Couplers Universal Adapter 3 Flex Coupler 2150 Co linear Flex Connector 923F Co axial to Co linear Adapter 923GCL 556CLA Co line...

Страница 33: ...hing 0 12 6 12 943 4DT AF6 SV4FA Roof Flashing 7 12 12 12 943S 4DT AF12 SV4B Flat Roof Flashing 943F SV4F Various Venting System Parts Wall Thimble 942 4DT WT SV4RSM Storm Collar 953 4DT SC SV4AC Deco...

Страница 34: ...other household equipment or appliances iii Damage due to chemicals dampness condensation or sulphur in the fuel supply lines which exceeds industry standards This warranty does not cover glass log br...

Страница 35: ...ate 4 coals 320B457 47 Wall mount plate 9000008 16 Restrictor plate 1 logs 320B396 48 Wiring harness 4000329 17 Restrictor plate 2 logs 320B397 49 Ceramic coal set 000B245 18 Restrictor plate 3 logs 3...

Страница 36: ...3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 36 37 37a 37b 38 39 40 41 42 43 44 44a 45 46 47 48 NG LPG 50 51 52 53 54 55 56 57 58 59 60 61 62 49 Replacem...

Отзывы: